1C /2C/2C+E/3C+E EPR Insulated H07 Submersible RubberCables 0.6/1kV Flexible Cu SAA Cable
Application:
A combination of robustness and flexibility makes rubber cables ideal to provide power supply to portable electrical equipment and devices. The mechanical stresses involved in moving apparatus require cables to withstand a high degree of wear-and-tear. The cables are designed to withstand extreme weather, oil/grease, mechanical as well as thermal stresses, also using compounds such as Ethylene Propylene Rubber (EPR) as insulating materials. These flexible rubber cables are suitable for a wide range of applications including mobile power supplies, light and heavy duty equipment, and submersible pumps, as welding cables providing power from the machine to the tool, for audio visual equipment, and equipment on construction sites.
Core Identification:
1C:White
2C:Brown,Blue
2C+E:Brown,Blue,Green/Yellow
3C+E: Brown,Black,Grey,Green/Yellow
Technical Data:
Voltage Rating:0.6/1kV
Operating Temperature:-40°C to +90°C
Short Circuit Temperature:250°C for 5 sec
Standards Compliance:
AS/NZS 5000.1
AS/NZS 3808
AS/NZS 1125
AS/NZS 1660.5.6 (Equivalent to IEC 60332-1)
1 core
Conductor Size (mm²) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Approx. Overall Diameter (mm) |
Min.Bending Radius(mm) | Approx. Weight (kg/km) |
|
During Installation |
After Installation |
|||||
6 | 3.09 | 1.0 | 8.4 | 69 | 37 | 118 |
10 | 4.36 | 1.2 | 10.5 | 87 | 46 | 179 |
16 | 5.44 | 1.2 | 11.8 | 97 | 52 | 253 |
25 | 6.88 | 1.4 | 14.1 | 116 | 62 | 374 |
35 | 8.59 | 1.4 | 16.2 | 134 | 71 | 490 |
50 | 10.38 | 1.6 | 19.0 | 157 | 84 | 679 |
70 | 11.68 | 1.6 | 20.6 | 170 | 91 | 904 |
95 | 13.51 | 1.8 | 23.4 | 193 | 103 | 1204 |
120 | 15.37 | 1.8 | 25.7 | 212 | 113 | 1478 |
150 | 16.4 | 2.0 | 27.5 | 227 | 121 | 1834 |
185 | 18.3 | 2.2 | 30.4 | 251 | 134 | 2245 |
240 | 20.8 | 2.4 | 34.0 | 281 | 150 | 2875 |
300 | 23.2 | 2.6 | 37.5 | 309 | 165 | 3559 |
Conductor Size (mm²) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Approx Overal Diameter (mm) |
Min.Bending Radius(mm) | Approx. Weight (kg/km) |
|
During Installation |
After Installation |
|||||
1 | 1.26 | 1.0 | 9.3 | 74 | 39 | 110 |
1.5 | 1.55 | 1.0 | 10.2 | 80 | 43 | 134 |
2.5 | 1.97 | 1.0 | 11.5 | 90 | 48 | 192 |
4 | 2.54 | 1.0 | 12.8 | 100 | 53 | 270 |
6 | 3.09 | 1.0 | 14.3 | 111 | 59 | 350 |
10 | 4.36 | 1.2 | 20.4 | 161 | 86 | 616 |
16 | 5.44 | 1.2 | 23.0 | 180 | 96 | 841 |
25 | 6.88 | 1.4 | 27.3 | 212 | 113 | 1222 |
35 | 8.5g | 1.4 | 31.1 | 245 | 130 | 1568 |
50 | 10.38 | 1.6 | 36.7 | 287 | 153 | 2149 |
Conductor Size (mm²) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Earth Conductor Size (mm²) |
Approx. Overal Diameter (mm |
Min.Bending Radius(mm) |
Approx. Weight (kg/km) |
|
During Installation |
After Installation |
||||||
1 | 1.26 | 1.0 | 1 | 10.0 | 79 | 42 | 130 |
1.5 | 1.55 | 1.0 | 1.5 | 11.0 | 86 | 46 | 160 |
2.5 | 1.97 | 1.0 | 2.5 | 12.3 | 96 | 51 | 231 |
4 | 2.54 | 1 | 4.00 | 14 | 107.00 | 57 | 328.00 |
6.0 | 3.09 | 1.0 | 6.00 | 15.3 | 119.00 | 63.0 | 430.00 |
10.0 | 4.36 | 1.2 | 10.00 | 21.9 | 172.00 | 92.0 | 748.00 |
16 | 5.44 | 1 | 16.00 | 25 | 192.00 | 102 | 1035.00 |
25.0 | 6.88 | 1.4 | 25.00 | 29.2 | 227.00 | 121.0 | 1516.00 |
35.0 | 8.59 | 1.4 | 35.00 | 33.5 | 263.00 | 140.0 | 1963.00 |
50 | 10.38 | 2 | 50.00 | 39 | 304.00 | 162 | 2705.00 |
70.0 | 11.68 | 1.6 | 70.00 | 42.4 | 333.00 | 178.0 | 3558.00 |
95.0 | 13.51 | 1.8 | 95.00 | 48.2 | 377.00 | 201.0 | 4721.00 |
120 | 15.37 | 2 | 120.00 | 54 | 422.00 | 225 | 5757.00 |
150.0 | 17.31 | 2.0 | 150.00 | 60.0 | 473.00 | 252.0 | 7127.00 |
185.0 | 18.51 | 2.2 | 185.00 | 64.5 | 506.00 | 270.0 | 8712.00 |
240 | 21.51 | 2 | 240.00 | 73 | 572.00 | 305 | 11119.00 |
300.0 | 23.79 | 2.62.6 | 300.00 | 80.2 | 632.00 | 337.0 | 12733.00 |
Conductor Size (mm²) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Earth Conductor Size (mm²) |
Approx Overal Diameter (mm) |
Min.Bending Radius(mm) |
Approx Weight (kg/km) |
|
During nstallation |
After Installation |
||||||
1 | 1.26 | 1.0 | 1 | 11.0 | 86 | 46 | 168 |
1.5 | 1.55 | 1.0 | 1.5 | 12.1 | 95 | 50 | 209 |
2.5 | 1.97 | 1.0 | 2.5 | 13.6 | 106 | 56 | 303 |
4 | 2.54 | 1.0 | 4 | 15.1 | 117 | 62 | 434 |
6 | 3.09 | 1.0 | 6 | 17.1 | 132 | 70 | 571 |
10 | 4.36 | 1.2 | 10 | 23.9 | 187 | 100 | 980 |
16 | 5.44 | 1.2 | 16 | 26.9 | 209 | 112 | 1367 |
25 | 6.88 | 1.4 | 25 | 32.3 | 254 | 135 | 2012 |
35 | 8.59 | 1.4 | 35 | 37.1 | 290 | 154 | 2615 |
50 | 10.38 | 1.6 | 50 | 43.1 | 338 | 180 | 3616 |
70 | 11.68 | 1.6 | 70 | 47.1 | 368 | 196 | 4772 |
95 | 13.51 | 1.8 | 95 | 53.9 | 419 | 224 | 6345 |
120 | 15.37 | 1.8 | 120 | 58.5 | 454 | 242 | 7751 |
150 | 17.31 | 2.0 | 150 | 66.6 | 522 | 278 | 9607 |
185 | 18.51 | 2.2 | 185 | 71.7 | 560 | 299 | 11754 |
240 | 21.51 | 2.4 | 240 | 81.5 | 641 | 342 | 15020 |
300 | 23.79 | 2.6 | 300 | 89.6 | 702 | 374 | 18569 |