Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Overhead, Underground |
Conductor Material: | Copper |
Sheath Material: | PVC |
Insulation Material: | Hepr |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Introduction | |
1 | Can be customized according to requirements. |
2 | Independent brand recruitment agency. |
3 | High quality, ISO 9001, CCC, CE, RoHS certified. |
4 | ODM&OEM is available. |
Suitable for the supply and transport of commands and/or signals in industry, construction sites, in housing. For use outdoor and indoor. For installation in brickwork, metal structures, gangways, pipes, ducts or similar closed systems.Allowed for underground laying also unprotected.
Type of the cables
Single-core | ||||||||||||
Formation |
Approx. conductor Ø |
Average insulation thickness |
Average sheath thickness |
Max. external Ø |
Max. electrical resistance at 20°C | Approx. cable weight |
Current rating A |
|||||
in air a 30°C |
in pipe in air at 30°C |
buried at 20°C |
buried pipe at 20°C | |||||||||
n° x mm2 | mm | mm | mm | mm | /km | kg/km | ||||||
K = 1 | K = 1,5 | K = 1 | K = 1,5 | |||||||||
1 x 1,5 | 1,5 | 0,7 | 1,4 | 6,7 | 13,3 | 43 | 24 | 20 | 26 | 24 | 23 | 21 |
1 x 2,5 | 2,0 | 0,7 | 1,4 | 7,2 | 7,98 | 54 | 33 | 28 | 34 | 31 | 29 | 27 |
1 x 4 | 2,5 | 0,7 | 1,4 | 7,8 | 4,95 | 68 | 45 | 37 | 43 | 40 | 38 | 35 |
1 x 6 | 3,0 | 0,7 | 1,4 | 8,4 | 3,30 | 91 | 58 | 48 | 55 | 51 | 48 | 44 |
1 x 10 | 4,0 | 0,7 | 1,4 | 9,4 | 1,91 | 140 | 80 | 66 | 73 | 68 | 64 | 59 |
1 x 16 | 5,0 | 0,7 | 1,4 | 10,4 | 1,21 | 190 | 107 | 88 | 96 | 89 | 83 | 77 |
1 x 25 | 6,2 | 0,9 | 1,4 | 12,2 | 0,780 | 280 | 141 | 117 | 124 | 115 | 108 | 100 |
1 x 35 | 7,4 | 0,9 | 1,4 | 13,6 | 0,554 | 370 | 176 | 144 | 150 | 139 | 131 | 121 |
1 x 50 | 8,9 | 1,0 | 1,4 | 15,4 | 0,386 | 510 | 216 | 175 | 186 | 173 | 162 | 150 |
1 x 70 | 10,5 | 1,1 | 1,4 | 17,3 | 0,272 | 700 | 279 | 222 | 229 | 212 | 199 | 184 |
1 x 95 | 12,2 | 1,1 | 1,5 | 19,4 | 0,206 | 905 | 342 | 269 | 270 | 250 | 234 | 217 |
1 x 120 | 13,8 | 1,2 | 1,5 | 21,4 | 0,161 | 1140 | 400 | 312 | 312 | 289 | 271 | 251 |
1 x 150 | 15,4 | 1,4 | 1,6 | 23,8 | 0,129 | 1420 | 464 | 355 | 356 | 330 | 310 | 287 |
1 x 185 | 16,9 | 1,6 | 1,6 | 26,0 | 0,106 | 1725 | 533 | 417 | 401 | 371 | 349 | 323 |
1 x 240 | 19,5 | 1,7 | 1,7 | 29,2 | 0,0801 | 2360 | 634 | 490 | 471 | 436 | 409 | 379 |
1 x 300 | 23,0 | 1,8 | 1,8 | 32,0 | 0,0641 | 2820 | 736 | - | 533 | 493 | 463 | 429 |
1 x 400 | 26,5 | 2,0 | 1,9 | 36,5 | 0,0486 | 3700 | 868 | - | 621 | 575 | 540 | 500 |
1 x 500 (*) | 28,5 | 2,2 | 2,1 | 37,1 | 0,0384 | 4605 | 998 | - | 705 | 650 | 610 | 560 |
1 x 630 (*) | 33,0 | 2,4 | 2,3 | 42,2 | 0,0287 | 6125 | 1151 | - | 823 | 762 | 716 | 663 |
(*) = This formation is without IMQ certificate Permissible current rating values are according to:
|
N.B. K=1: resistivity of the ground equal to 1,0 K·m/W K=1,5: resistivity of the ground equal to 1,5 K·m/W |
Two-core | ||||||||||||
Formation |
Approx. conductor Ø |
Average insulation thickness |
Average sheath thickness |
Max. external Ø |
Max. electrical resistance at 20°C | Approx. cable weight |
Current rating A |
|||||
in air at 30°C |
in pipe in air at 30°C |
buried at 20°C |
buried pipe at 20°C | |||||||||
n° x mm2 | mm | mm | mm | mm | /km | kg/km | ||||||
K = 1 | K = 1,5 | K = 1 | K = 1,5 | |||||||||
2 x 1,5 | 1,5 | 0,7 | 1,8 | 12,0 | 13,3 | 120 | 26 | 22 | 28 | 26 | 25 | 23 |
2 x 2,5 | 2,0 | 0,7 | 1,8 | 13,0 | 7,98 | 150 | 36 | 30 | 37 | 35 | 32 | 30 |
2 x 4 | 2,5 | 0,7 | 1,8 | 14,2 | 4,95 | 195 | 49 | 40 | 48 | 45 | 41 | 39 |
2 x 6 | 3,0 | 0,7 | 1,8 | 15,4 | 3,30 | 250 | 63 | 51 | 60 | 56 | 52 | 49 |
2 x 10 | 4,0 | 0,7 | 1,8 | 17,3 | 1,91 | 365 | 86 | 69 | 80 | 76 | 70 | 66 |
2 x 16 | 5,0 | 0,7 | 1,8 | 19,4 | 1,21 | 510 | 115 | 91 | 105 | 99 | 91 | 86 |
2 x 25 | 6,2 | 0,9 | 1,8 | 23,0 | 0,780 | 760 | 149 | 119 | 135 | 128 | 118 | 111 |
2 x 35 | 7,4 | 0,9 | 1,8 | 25,7 | 0,554 | 1010 | 185 | 140 | 166 | 156 | 144 | 136 |
2 x 50 | 8,9 | 1,0 | 1,8 | 29,3 | 0,386 | 1390 | 225 | 175 | 205 | 193 | 178 | 168 |
Permissible current rating values are according to:
|
N.B. K=1: resistivity of the ground equal to 1,0 K·m/W K=1,5: resistivity of the ground equal to 1,5 K·m/W |
Three-core | ||||||||||||
Formation |
Approx. conductor Ø |
Average insulation thickness |
Average sheath thickness |
Max. external Ø |
Max. electrical resistance at 20°C | Approx. cable weight |
Current rating A |
|||||
in air at 30°C |
in pipe in air at 30°C |
buried at 20°C |
buried pipe at 20°C | |||||||||
n° x mm2 | mm | mm | mm | mm | /km | kg/km | ||||||
K = 1 | K = 1,5 | K = 1 | K = 1,5 | |||||||||
3 x 1,5 | 1,5 | 0,7 | 1,8 | 12,5 | 13,3 | 135 | 23 | 19 | 23 | 22 | 20 | 19 |
3 x 2,5 | 2,0 | 0,7 | 1,8 | 13,6 | 7,98 | 170 | 32 | 26 | 30 | 29 | 27 | 25 |
3 x 4 | 2,5 | 0,7 | 1,8 | 14,9 | 4,95 | 230 | 42 | 35 | 39 | 37 | 34 | 32 |
3 x 6 | 3,0 | 0,7 | 1,8 | 16,2 | 3,30 | 300 | 54 | 44 | 50 | 47 | 43 | 41 |
3 x 10 | 4,0 | 0,7 | 1,8 | 18,2 | 1,91 | 445 | 75 | 60 | 67 | 63 | 58 | 55 |
3 x 16 | 5,0 | 0,7 | 1,8 | 20,6 | 1,21 | 640 | 100 | 80 | 88 | 83 | 76 | 72 |
3 x 25 | 6,2 | 0,9 | 1,8 | 24,5 | 0,780 | 950 | 127 | 105 | 113 | 107 | 99 | 93 |
3 x 35 | 7,4 | 0,9 | 1,8 | 27,3 | 0,554 | 1280 | 158 | 128 | 139 | 131 | 121 | 114 |
3 x 50 | 8,9 | 1,0 | 1,8 | 31,2 | 0,386 | 1780 | 192 | 154 | 172 | 162 | 149 | 141 |
3 x 70 | 10,5 | 1,1 | 1,9 | 35,6 | 0,272 | 2474 | 246 | 194 | 212 | 200 | 184 | 174 |
3 x 95 | 12,2 | 1,1 | 2,0 | 40,0 | 0,206 | 3160 | 298 | 233 | 251 | 237 | 218 | 206 |
3 x 120 | 13,8 | 1,2 | 2,1 | 44,4 | 0,161 | 4020 | 346 | 268 | 290 | 274 | 252 | 238 |
3 x 150 | 15,4 | 1,4 | 2,3 | 49,5 | 0,129 | 5240 | 399 | 300 | 332 | 313 | 288 | 272 |
3 x 185 | 16,9 | 1,6 | 2,4 | 55,2 | 0,106 | 6365 | 456 | 340 | 373 | 352 | 324 | 306 |
3 x 240 | 19,5 | 1,7 | 2,6 | 61,9 | 0,0801 | 8270 | 538 | 398 | 439 | 414 | 382 | 360 |
3 x 300 | 22,0 | 1,8 | 2,8 | 68,0 | 0,0641 | 10210 | 621 | - | - | - | - | - |
Permissible current rating values are according to:
|
N.B. K=1: resistivity of the ground equal to 1,0 K·m/W K=1,5: resistivity of the ground equal to 1,5 K·m/W |
Four-core | ||||||||||||
Formation |
Approx. conductor Ø |
Average insulation thickness |
Average sheath thickness |
Max. exter- nal Ø |
Max. electrical resistance at 20°C | Approx. cable weight |
Current rating A |
|||||
in air at 30°C |
in pipe in air at 30°C |
buried at 20°C |
buried pipe at 20°C | |||||||||
n° x mm2 | mm | mm | mm | mm | /km | kg/km | ||||||
K = 1 | K = 1,5 | K = 1 | K = 1,5 | |||||||||
4 x 1,5 | 1,5 | 0,7 | 1,8 | 13,4 | 13,3 | 155 | 23 | 19 | 23 | 22 | 20 | 19 |
4 x 2,5 | 2,0 | 0,7 | 1,8 | 14,6 | 7,98 | 205 | 32 | 26 | 30 | 29 | 27 | 25 |
4 x 4 | 2,5 | 0,7 | 1,8 | 16,0 | 4,95 | 275 | 42 | 35 | 39 | 37 | 34 | 32 |
4 x 6 | 3,0 | 0,7 | 1,8 | 17,5 | 3,30 | 365 | 54 | 44 | 50 | 47 | 43 | 41 |
4 x 10 | 4,0 | 0,7 | 1,8 | 19,8 | 1,91 | 550 | 75 | 60 | 67 | 63 | 58 | 55 |
4 x 16 | 5,0 | 0,7 | 1,8 | 22,4 | 1,21 | 790 | 100 | 80 | 88 | 83 | 76 | 72 |
4 x 25 | 6,2 | 0,9 | 1,8 | 26,8 | 0,780 | 1200 | 127 | 105 | 113 | 107 | 99 | 93 |
3x35+25 | 7,4/6,2 | 0,9/0,9 | 1,8 | 29,2 | 0,554/0,780 | 1520 | 158 | 128 | 139 | 131 | 121 | 114 |
3x50+25 | 8,9/6,2 | 1,0/0,9 | 1,8 | 32,4 | 0,386/0,780 | 2015 | 192 | 154 | 172 | 162 | 149 | 141 |
3x70+35 | 10,5/7,4 | 1,1/0,9 | 1,9 | 37,0 | 0,272/0,554 | 2800 | 246 | 194 | 212 | 200 | 184 | 174 |
3x95+50 | 12,2/8,9 | 1,1/1,0 | 2,1 | 42,0 | 0,206/0,386 | 3635 | 298 | 233 | 251 | 237 | 218 | 206 |
3x120+70 | 13,8/10,5 | 1,2/1,1 | 2,2 | 46,9 | 0,161/0,272 | 4695 | 346 | 268 | 290 | 274 | 252 | 238 |
3x150+95 | 15,4/12,2 | 1,4/1,1 | 2,4 | 52,5 | 0,129/0,206 | 6060 | 399 | 300 | 332 | 313 | 288 | 272 |
3x185+95 | 16,9/12,2 | 1,6/1,1 | 2,5 | 57,3 | 0,106/0,206 | 7150 | 456 | 340 | 373 | 352 | 324 | 306 |
3x240+150 | 19,5/15,4 | 1,7/1,4 | 2,7 | 65,5 | 0,0801/0,129 | 9310 | 538 | 398 | 439 | 414 | 382 | 360 |
3x300+150 | 22,0/15,4 | 1,8/1,4 | 2,9 | 70,8 | 0,0641/0,129 | 11420 | 621 | 455 | - | - | - | - |
Permissible current rating values are according to:
|
N.B. K=1: resistivity of the ground equal to 1,0 K·m/W K=1,5: resistivity of the ground equal to 1,5 K·m/W |
Five-core | ||||||||||||
Formation |
Approx. conductor Ø |
Average insulation thickness |
Average sheath thickness |
Max. external Ø |
Max. electrical resistance at 20°C | Approx. cable weight |
Current rating A |
|||||
in air at 30°C |
in pipe in air at 30°C |
buried at 20°C |
buried pipe at 20°C | |||||||||
n° x mm2 | mm | mm | mm | mm | /km | kg/km | ||||||
K = 1 | K = 1,5 | K = 1 | K = 1,5 | |||||||||
5G1,5 | 1,5 | 0,7 | 1,8 | 14,4 | 13,3 | 180 | 23 | 19 | 23 | 22 | 20 | 19 |
5G2,5 | 2,0 | 0,7 | 1,8 | 15,6 | 7,98 | 235 | 32 | 26 | 30 | 29 | 27 | 25 |
5G4 | 2,5 | 0,7 | 1,8 | 17,3 | 4,95 | 320 | 42 | 35 | 39 | 37 | 34 | 32 |
5G6 | 3,0 | 0,7 | 1,8 | 18,9 | 3,30 | 430 | 54 | 44 | 50 | 47 | 43 | 41 |
5G10 | 4,0 | 0,7 | 1,8 | 21,5 | 1,91 | 650 | 75 | 60 | 67 | 63 | 58 | 55 |
5G16 | 5,0 | 0,7 | 1,8 | 24,4 | 1,21 | 965 | 100 | 80 | 88 | 86 | 76 | 72 |
5G25 | 6,2 | 0,9 | 1,8 | 29,3 | 0,780 | 1460 | 127 | 105 | 113 | 107 | 99 | 93 |
5G35 | 7,4 | 0,9 | 1,8 | 32,8 | 0,554 | 1980 | 158 | 128 | 139 | 131 | 121 | 114 |
5G50 | 8,9 | 1,0 | 2,0 | 38,2 | 0,386 | 2930 | 192 | 154 | 172 | 162 | 149 | 141 |
Permissible current rating values are according to:
|
N.B. K=1: resistivity of the ground equal to 1,0 K·m/W K=1,5: resistivity of the ground equal to 1,5 K·m/W |
Multi-core / signalling and control | ||||||||||
Formation (*) |
Approx. conductor Ø |
Average insulation thickness |
Average sheath thickness |
Max. external Ø |
Max. electrical resistance at 20°C | Approx. cable weight |
Current rating A |
|||
n° x mm2 |
mm |
mm |
mm |
mm |
/km |
kg/km |
in air at 30°C |
in pipe in air at 30°C |
buried pipe at 20°C | |
K = 1 | K = 1,5 | |||||||||
7G1,5 | 1,5 | 0,7 | 1,8 | 15,4 | 13,3 | 220 | 13 | 11,5 | 18,5 | 16 |
10G1,5 | 1,5 | 0,7 | 1,8 | 18,7 | 13,4 | 300 | 13 | 11,5 | 18,5 | 16 |
12G1,5 | 1,5 | 0,7 | 1,8 | 19,3 | 13,4 | 330 | 11 | 9,5 | 14,5 | 12,5 |
16G1,5 | 1,5 | 0,7 | 1,8 | 21,1 | 13,4 | 420 | 11 | 9,5 | 14,5 | 12,5 |
19G1,5 | 1,5 | 0,7 | 1,8 | 22,1 | 13,4 | 470 | 9 | 8 | 13 | 11,5 |
24G1,5 | 1,5 | 0,7 | 1,8 | 25,4 | 13,5 | 575 | 9 | 8 | 13 | 11,5 |
7G2,5 | 2,0 | 0,7 | 1,8 | 16,8 | 7,98 | 305 | 17,5 | 15,5 | 24 | 21 |
10G2,5 | 2,0 | 0,7 | 1,8 | 20,6 | 8,06 | 415 | 17,5 | 15,5 | 24 | 21 |
12G2,5 | 2,0 | 0,7 | 1,8 | 21,3 | 8,06 | 470 | 13,5 | 12 | 20 | 17,5 |
16G2,5 | 2,0 | 0,7 | 1,8 | 23,3 | 8,06 | 605 | 13,5 | 12 | 20 | 17,5 |
19G2,5 | 2,0 | 0,7 | 1,8 | 24,5 | 8,06 | 680 | 12 | 10,5 | 16 | 14 |
24G2,5 | 2,0 | 0,7 | 1,8 | 28,3 | 8,10 | 835 | 12 | 10,5 | 16 | 14 |
(*) also available without the green/yellow N.B. Permissible current rating values are according to:
|
N.B. K=1: resistivity of the ground equal to 1,0 K·m/W K=1,5: resistivity of the ground equal to 1,5 K·m/W |
Suppliers with verified business licenses