• Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
  • Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
  • Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
  • Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
  • Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
  • Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables

Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables

Type: Insulated
Conductor Type: Stranded
Application: Overhead, Heating, Underground
Conductor Material: Copper
Sheath Material: PE
Insulation Material: XLPE
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
Medium voltage cable
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CE, UL, CCC, RoHS, VDE
Brand
Feiya
Color
Black Red Yellow, According to Voltage Level
Whether It Is Environmentally Friendly
Yes
Whether Quality Inspection
Provide Inspection Certificate
Standard
Customized According to Specified National Standar
OEM/ODM
Accepted
Core
Single Core and Multicore
Transport Package
Standard Export Packaging
Specification
International General Specifications
Trademark
Fengda
Origin
Tianjin, China(Mainland)
HS Code
8544492100
Production Capacity
100000/Day

Product Description

Introduction
1 Can be customized according to requirements.
2 Independent brand recruitment agency.
3 High quality, ISO 9001, CCC, CE, RoHS certified.
4 ODM&OEM is available.
 

Application

These cables are designed to be used for the supply of electrical energy in fixed applications up to the rated voltages at a nominal power frequency between 49Hz and 61Hz, they are suitable for use in distribution installation, electrical power station , they are applied for installation, outdoors, underground where subject to mechanical damage.

Standard

AS/NZS 1429.1



Cable Construction
Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables

  • CONDUCTOR: Plain circular compacted copper to AS/NZS1125 Maximum Continuous Operating Temperature: 90°C
  • CONDUCTOR SCREEN: Extruded semi-conducting compound, bonded to the insulation and applied in the same operation as the insulation
  • INSULATION: Cross Linked Polyethylene (XLPE) - standard Ethylene Propylene Rubber (EPR) - alternative
  • INSULATION SCREEN: Extruded semi-conducting compound
  • METALLIC SCREEN: Plain annealed copper wire: 10kA for nominal 1 second(HEAVY DUTY)
  • BEDDING: PVC
  • ARMOURING: Galvanised steel wires
  • SHEATH: Black 5V-90 polyvinyl chloride (PVC) - standard
  • Orange 5V-90 PVC inner plus black high density polyethylene (HDPE) outer - alternative Low smoke zero halogen (LSOH) - alternative

Technical Characteristics

NOMINAL COND UCTOR AREA MAXIMUM CONDUCTOR DC RESISTANCE AT 20°C COND. AC RESISTANCE AT 50HZ AND 90°C INDUCTIVE REACTANCE AT 50HZ INSUL ATION RESIS TANCE AT 20°C CONDUCTOR TO SCREEN CAPACI TANCE CHARGING CURRENT PER PHASE DIEL ECTRIC LOSS PER PHRASE MAXIMUM DIAELECTRIC STRESS SCREEN DC RESIST ANCE AT 20°C ARMOUR DC RESISTA NCE AT 20°C ZERO SEQUE NCE RESIST ANCE AT 20°C ZERO SEQ. REACT. AT 50HZ
MM2 OHM /KM OHM /KM OHM /KM MEGOHM. KM ΜF X KM A X KM W X KM KV X MM OHM /KM OHM /KM OHM/KM OHM/KM
16 1.15 1.47 0.134 11000 0.221 0.263 4 2.06 1.06 0.857 2.58 0.0842
25 0.727 0.927 0.127 9700 0.248 0.296 4.5 1.99 0.706 0.811 1.86 0.077
35 0.524 0.668 0.12 8700 0.276 0.33 5.01 1.93 0.533 0.657 1.41 0.0712
50 0.387 0.494 0.115 7800 0.308 0.368 5.59 1.87 0.366 0.616 1.08 0.066
70 0.268 0.342 0.109 6900 0.352 0.42 6.39 1.82 0.265 0.559 0.807 0.0603
95 0.193 0.247 0.101 6000 0.404 0.482 7.33 1.77 0.265 0.521 0.721 0.0525
120 0.153 0.196 0.0969 5400 0.447 0.534 8.11 1.74 0.266 0.487 0.669 0.0491
150 0.124 0.16 0.0942 5000 0.486 0.58 8.81 1.72 0.265 0.458 0.629 0.0467
185 0.0991 0.128 0.0917 4600 0.53 0.632 9.61 1.69 0.265 0.431 0.593 0.0443
240 0.0754 0.0986 0.089 4200 0.576 0.687 10.4 1.61 0.266 0.307 0.504 0.0418
300 0.0601 0.0798 0.0879 4000 0.597 0.713 10.8 1.49 0.265 0.284 0.473 0.0409
400 0.047 0.064 0.0852 3800 0.627 0.749 11.4 1.38 0.265 0.257 0.44 0.0384

Cable Parameter

SECTIONAL AREA OF CONDUCTOR NOM. CONDUCTOR DIAMETER NOM. INSULATION THICKNESS NOM. DIAMETE OVER INSULATION SCREEN AREA ON CORES NO. AND DIAMTER OF SCREENED WIRES NOM. DIAMETE OVER SCREENED WIRES NOM. DIAMETE OVER BEDDING NOM. DIAMETE OF ARMOUR NOM. DIAMETE OVER ARMOUR NOM. OVERALL DIAMETER APPROX. MASS
MM2 MM MM MM MM2 NO X MM MM MM MM MM MM KG/100M
16 4.8 2.5 11 17 10 x 0.85 14.3 34 2 38 42.6 295
25 5.8 2.5 12 25.5 15 x 0.85 15.3 36.1 2 40.1 44.9 345
35 6.8 2.5 13 34 20 x 0.85 16.3 38.5 2.5 43.5 48.7 440
50 8 2.5 14.1 49.4 29 x 0.85 17.4 41 2.5 46 51.4 515
70 9.6 2.5 15.7 68.1 40 x 0.85 19 44.6 2.5 49.6 55.2 630
95 11.5 2.5 17.6 68.1 40 x 0.85 20.9 48.9 2.5 53.9 59.7 745
120 13.1 2.5 19.2 68.1 40 x 0.85 22.5 52.3 2.5 57.3 63.3 850
150 14.5 2.5 20.6 68.1 40 x 0.85 23.9 55.7 2.5 60.7 66.9 960
185 16.1 2.5 22.2 68.1 40 x 0.85 25.5 59.4 2.5 64.4 70.8 1090
240 18.5 2.6 24.9 68.1 40 x 0.85 28.2 65.3 3.15 71.6 78.6 1410
300 20.7 2.8 27.6 68.1 40 x 0.85 30.9 71.4 3.15 77.7 85.2 1660
400 23.6 3 30.9 68.1 40 x 0.85 34.2 78.8 3.15 85.1 92.9 2030

 

Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables
Australian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power CablesAustralian Standard (MV) 3.8/6.6kv Cu Conductor XLPE/Epr Insulated Three Core Individual Screened /PVC/Swa/PVC/PE Sheathed Armoured Power Cables

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now