Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car, Under Sea |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Description
Specifications:
Cable type |
Description |
CJV/DA/SA |
XLPE insulated PVC outer sheath shipboard power cable, type DA,SA |
CJY/SC |
XLPE insulated PO outer sheath Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard power cable, type SC |
CJVR/DA/SA |
XLPE insulated PVC outer sheath shipboard flexible power cable, type DA,SA |
CJYR/SC |
XLPE insulated PO outer sheath Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard flexible power cable, type SC |
CJV90DA/SA |
XLPE insulated PVC inner sheath galvanized steel wire braided shipboard power cable, type DA,SA |
CJV80/DA/SA |
XLPE insulated PVC inner sheathed tinned copper wire braided shipboard power cable, type DA,SA |
CJY90/SC |
XLPE insulated PO inner sheathed galvanized steel wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard power cable, type SC |
CJY80/SC |
XLPE insulated PO inner sheathed tinned copper wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard power cable, type SC |
CJVR90/DA/SA |
XLPE insulated PVC inner sheathed galvanized steel wire braided shipboard flexible power cable, type DA,SA |
CJVR80/DA/SA |
XLPE insulated PVC inner sheathed tinned copper wire braided shipboard flexible power cable, type DA,SA |
CJYR90/SC |
XLPE insulated PO inner sheathed galvanized steel wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard flexible power cable, type SC |
CJYR80/SC |
XLPE insulated PO inner sheathed tinned copper wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard flexible power cable, type SC |
CJV92/DA/SA |
XLPE insulated PVC inner sheath galvanized steel wire braided PVC outer sheath shipboard power cable, type DA,SA |
CJV82/DA/SA |
XLPE insulated PVC inner sheathed tinned copper wire braided PVC outer sheath shipboard power cable, type DA,SA |
CJY93/SC |
XLPE insulated PO inner and outer sheathed galvanized steel wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard cable, type SC |
CJY83/SC |
XLPE insulated PO inner and outer sheathed tinned copper wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard cable, type SC |
CJVR92/DA/SA |
XLPE insulated PVC inner sheath galvanized steel wire braided PVC outer sheath shipboard flexible power cable, type DA,SA |
CJVR82/DA/SA |
XLPE insulated PVC inner sheathed tinned copper wire braided PVC outer sheath shipboard flexible power cable, type DA,SA |
CJYR93/SC |
XLPE insulated PO inner and outer sheathed galvanized steel wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard flexible cable, type SC |
CJYR83/SC |
XLPE insulated PO inner and outer sheathed tinned copper wire braided Halogen-free, Low-smoke, Low-toxicity flame retardant shipboard flexible cable, type SC |
CEF/DA/SA |
EPR insulated PCP sheath shipboard power cable, type DA,SA |
CEH/DA/SA |
EPR insulated CSP sheath shipboard power cable, type DA,SA |
CEV/DA/SA |
EPR insulated PVC sheath shipboard power cable, type DA,SA |
CEF90/DA/SA |
EPR insulation PCP inner sheath galvanized steel wire braided shipboard power cable, type DA,SA |
CEF80/DA/SA |
EPR insulation PCP inner sheath tinned copper wire braided shipboard power cable, type DA,SA |
CEH90/DA/SA |
EPR insulation CSP inner sheath galvanized steel wire braided shipboard power cable, type DA,SA |
CEH80/DA/SA |
EPR insulation CSP inner sheath tinned copper wire braided shipboard power cable, type DA,SA |
CEV90/DA/SA |
EPR insulation PVC inner sheath galvanized steel wire braided shipboard power cable, type DA,SA |
CEV80/DA/SA |
EPR insulation PVC inner sheath tinned copper wire braided shipboard power cable, type DA,SA |
CEF92/DA/SA |
EPR insulation PCP inner sheath PVC outer sheath galvanized steel wire braided shipboard power cable, type DA,SA |
CEF82/DA/SA |
EPR insulation PCP inner sheath PVC outer sheathed tinned copper wire braided shipboard power cable, type DA,SA |
CEH92/DA/SA |
EPR insulation CSP inner sheath PVC outer sheath galvanized steel wire braided shipboard power cable, type DA,SA |
CEH82DA/SA |
EPR insulation CSP inner sheath PVC outer sheathed tinned copper wire braided shipboard power cable, type DA,SA |
CEV92/DA/SA |
EPR insulation PVC inner sheath PVC outer sheathed galvanized steel wire braided shipboard power cable, type DA,SA |
CEV82/DA/SA |
EPR insulation PVC inner sheath PVC outer sheathed tinned copper wire braided shipboard power cable, type DA,SA |
CEFR/DA/SA |
EPR insulated PCP sheath shipboard power flexible cable, type DA,SA |
CEHR/DA/SA |
EPR insulated CSP sheath shipboard power flexible cable, type DA,SA |
CEVR/DA/SA |
EPR insulated PVC sheath shipboard power flexible cable, type DA,SA |
CEFR90/DA/SA |
EPR insulation PCP inner sheath galvanized steel wire braided shipboard power flexible cable, type DA,SA |
CEFR80/DA/SA |
EPR insulation PCP inner sheath tinned copper wire braided shipboard power flexible cable, type DA,SA |
CEHR90/DA/SA |
EPR insulation CSP inner sheath galvanized steel wire braided shipboard power flexible cable, type DA,SA |
CEHR80/DA/SA |
EPR insulation CSP inner sheath tinned copper wire braided shipboard power flexible cable, type DA,SA |
CEVR90/DA/SA |
EPR insulated PVC inner sheath galvanized steel wire braided shipboard power flexible cable, type DA,SA |
CEVR80/DA/SA |
EPR insulated PVC inner sheath tinned copper wire braided shipboard power flexible cable, type DA,SA |
CEFR92/DA/SA |
EPR insulation PCP inner sheath PVC outer sheath galvanized steel wire braided shipboard power flexible cable, type DA,SA |
CEFR82/DA/SA |
EPR insulation PCP inner sheath PVC outer sheathed tinned copper wire braided shipboard power flexible cable, type DA,SA |
CEHR92/DA/SA |
EPR insulation CSP inner sheath PVC outer sheath galvanized steel wire braided shipboard power flexible cable, type DA,SA |
CEHR82/DA/SA |
EPR insulation CSP inner sheath PVC outer sheathed tinned copper wire braided shipboard power flexible cable, type DA,SA |
CEVR92/DA/SA |
EPR insulation PVC inner sheath PVC outer sheath galvanized steel wire braided shipboard power flexible cable, type DA,SA |
CEVR82/DA/SA |
EPR insulation PVC inner sheath PVC outer sheathed tinned copper wire braided shipboard power flexible cable, type DA,SA |
Construction:
conductor:Stranded annealed copper/tinned copper
Insulated:Low smoke,halogen free xple /EPR insulation.
Inner sheath:XLPE/PVC
Outer sheath:PVC/XLPE/XLPO
Braid:non-braid or metal wire braid
Shield:100% foil below shield
1)3.6/6(7.2)kV, 3.6/6.6(7.2)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
3 X 25 | 6 | 2.5 | 0.1 | 1.2 | 0.2 | 1.9 | 37.9 | 1.87 | 2.32 |
3 X 35 | 6.9 | 2.5 | 0.1 | 1.3 | 0.5 | 2 | 41.5 | 2.1 | 2.73 |
3 X50 | 8.2 | 2.5 | 0.1 | 1.3 | 0.5 | 2 | 44.3 | 2.37 | 3.22 |
3 X 70 | 9.7 | 2.5 | 0.1 | 1.4 | 0.5 | 2.1 | 47.9 | 2.77 | 4 |
3 X 95 | 11.3 | 2.5 | 0.1 | 1.4 | 0.5 | 2.2 | 51.6 | 3.21 | 4.91 |
3 X 120 | 12.8 | 2.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.4 | 3.69 | 5.84 |
3 X 150 | 14.2 | 2.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 4.15 | 6.85 |
3 X 185 | 15.9 | 2.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.5 | 4.73 | 8.11 |
3 X 240 | 18.3 | 2.6 | 0.1 | 1.6 | 0.5 | 2.7 | 68.5 | 5.62 | 10.05 |
3 X 300 | 20.4 | 2.8 | 0.1 | 1.7 | 0.5 | 2.9 | 74.5 | 6.55 | 12.11 |
3 X 400 | 23.2 | 3 | 0.1 | 1.9 | 0.8 | 3.2 | 83.6 | 8.78 | 15.86 |
3 X 500 | 26.4 | 3.2 | 0.1 | 2.1 | 0.8 | 3.4 | 93 | 10.52 | 18.85 |
2)6/10(12)kV, 6.35/11(12)kV, , Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
3 X 25 | 6 | 3.4 | 0.1 | 1.3 | 0.5 | 2 | 43.4 | 2.16 | 2.61 |
3 X 35 | 6.9 | 3.4 | 0.1 | 1.3 | 0.5 | 2 | 45.4 | 2.36 | 2.99 |
3 X50 | 8.2 | 3.4 | 0.1 | 1.4 | 0.5 | 2.2 | 48.8 | 2.69 | 3.54 |
3 X 70 | 9.7 | 3.4 | 0.1 | 1.5 | 0.5 | 2.3 | 52.4 | 3.1 | 4.33 |
3 X 95 | 11.3 | 3.4 | 0.1 | 1.5 | 0.5 | 2.4 | 56.1 | 3.56 | 5.26 |
3 X 120 | 12.8 | 3.4 | 0.1 | 1.5 | 0.5 | 2.5 | 59.5 | 4.04 | 6.19 |
3 X 150 | 14.2 | 3.4 | 0.1 | 1.5 | 0.5 | 2.6 | 62.7 | 4.49 | 7.19 |
3 X 185 | 15.9 | 3.4 | 0.1 | 1.6 | 0.5 | 2.6 | 66.6 | 5.12 | 8.49 |
3 X 240 | 18.3 | 3.4 | 0.1 | 1.7 | 0.5 | 2.8 | 72.4 | 5.99 | 10.42 |
3 X 300 | 20.4 | 3.4 | 0.1 | 1.8 | 0.5 | 3 | 77.5 | 6.86 | 12.42 |
3 X 400 | 23.2 | 3.4 | 0.1 | 1.9 | 0.8 | 3.2 | 85.4 | 8.97 | 16.05 |
3 X 500 | 26.4 | 3.4 | 0.1 | 2 | 0.8 | 3.4 | 93.7 | 10.65 | 19.5 |
3)8.7/10(15)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
3 X 25 | 6 | 4.5 | 0.1 | 1.4 | 0.5 | 2.1 | 48.6 | 2.53 | 2.98 |
3 X 35 | 6.9 | 4.5 | 0.1 | 1.4 | 0.5 | 2.2 | 50.7 | 2.76 | 3.39 |
3 X50 | 8.2 | 4.5 | 0.1 | 1.5 | 0.5 | 2.3 | 53.9 | 3.1 | 3.95 |
3 X 70 | 9.7 | 4.5 | 0.1 | 1.5 | 0.5 | 2.4 | 57.4 | 3.51 | 4.74 |
3 X 95 | 11.3 | 4.5 | 0.1 | 1.5 | 0.5 | 2.6 | 61.2 | 4.05 | 5.75 |
3 X 120 | 12.8 | 4.5 | 0.1 | 1.6 | 0.5 | 2.6 | 64.7 | 4.56 | 6.72 |
3 X 150 | 14.2 | 4.5 | 0.1 | 1.6 | 0.5 | 2.7 | 67.9 | 5.04 | 7.74 |
3 X 185 | 15.9 | 4.5 | 0.1 | 1.7 | 0.5 | 2.8 | 71.9 | 5.66 | 9.04 |
3 X 240 | 18.3 | 4.5 | 0.1 | 1.8 | 0.5 | 3 | 77.7 | 6.56 | 11 |
3 X 300 | 20.4 | 4.5 | 0.1 | 1.9 | 0.8 | 3.2 | 84.1 | 8.39 | 13.96 |
3 X 400 | 23.2 | 4.5 | 0.1 | 2 | 0.8 | 3.3 | 90.5 | 9.71 | 16.79 |
3 X 500 | 26.4 | 4.5 | 0.1 | 2.1 | 0.8 | 3.5 | 98.8 | 11.45 | 20.57 |
4)12/20(24)kV, 12.7/22(24)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
3 X 25 | |||||||||
3 X 35 | 6.9 | 5.5 | 0.1 | 1.5 | 0.5 | 2.4 | 55.6 | 3.14 | 3.77 |
3 X50 | 8.2 | 5.5 | 0.1 | 1.5 | 0.5 | 2.5 | 58.6 | 3.49 | 4.34 |
3 X 70 | 9.7 | 5.5 | 0.1 | 1.5 | 0.5 | 2.6 | 62.1 | 3.93 | 5.16 |
3 X 95 | 11.3 | 5.5 | 0.1 | 1.6 | 0.5 | 2.6 | 65.7 | 4.46 | 6.16 |
3 X 120 | 12.8 | 5.5 | 0.1 | 1.7 | 0.5 | 2.7 | 69.4 | 5 | 7.15 |
3 X 150 | 14.2 | 5.5 | 0.1 | 1.7 | 0.5 | 2.8 | 72.6 | 5.49 | 8.19 |
3 X 185 | 15.9 | 5.5 | 0.1 | 1.8 | 0.5 | 3 | 76.9 | 6.16 | 9.53 |
3 X 240 | 18.3 | 5.5 | 0.1 | 1.9 | 0.8 | 3.2 | 83.9 | 7.87 | 12.31 |
3 X 300 | 20.4 | 5.5 | 0.1 | 2 | 0.8 | 3.2 | 88.6 | 8.96 | 14.52 |
3 X 400 | 23.2 | 5.5 | 0.1 | 2.1 | 0.8 | 3.5 | 95.4 | 10.35 | 17.43 |
3 X 500 | 26.4 | 5.5 | 0.1 | 2.2 | 0.8 | 3.7 | 103.7 | 12.45 | 20.23 |
5)18/30(36)kV, 19/33(36)kV, Three Cores, Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable | |||||||||
No. X Nominal Cross Section of Conductor | Nominal Diameter of Conductor | Nominal Thickness of Insulation | Nominal Thickness of Copper Tape Screen | Nominal Thickness of Inner Sheath | Nominal Thickness of Steel Tape Armouring | Nominal Thickness of PVC Sheath | Approx. Overall Diameter | Approx. Weight | |
Al Conductor | Cu Conductor | ||||||||
No. X mm 2 | mm | mm | mm | mm | mm | mm | mm | Kg/m | Kg/m |
3 X 25 | |||||||||
3 X 35 | |||||||||
3 X50 | 8.2 | 8 | 0.1 | 1.7 | 0.5 | 2.8 | 70.4 | 4.56 | 5.41 |
3 X 70 | 9.7 | 8 | 0.1 | 1.7 | 0.5 | 2.9 | 73.9 | 5.04 | 6.26 |
3 X 95 | 11.3 | 8 | 0.1 | 1.8 | 0.5 | 3 | 77.7 | 5.62 | 7.32 |
3 X 120 | 12.8 | 8 | 0.1 | 1.9 | 0.8 | 3.2 | 82.8 | 6.99 | 9.15 |
3 X 150 | 14.2 | 8 | 0.1 | 1.9 | 0.8 | 3.2 | 85.8 | 7.56 | 10.26 |
3 X 185 | 15.9 | 8 | 0.1 | 2 | 0.8 | 3.3 | 89.9 | 8.3 | 11.67 |
3 X 240 | 18.3 | 8 | 0.1 | 2.1 | 0.8 | 3.5 | 95.7 | 9.36 | 13.79 |
3 X 300 | 20.4 | 8 | 0.1 | 2.2 | 0.8 | 3.6 | 100.6 | 10.51 | 16.07 |
3 X 400 | 23.2 | 8 | 0.1 | 2.3 | 0.8 | 3.8 | 107.2 | 11.99 | 19.07 |
3 X 500 | 26.4 | 8 | 0.1 | 2.4 | 0.8 | 4 | 120.1 | 14.15 | 23.85 |
FAQ
Q1:Are you a trading company or manufacturer?
A1: Tianjin Feiya wire & Cable CO., LTD. is a professional manufacturer.
Q2: What kinds of products does Tianjin Feiya wire & Cable CO., LTD. manufacture?
A2: Our products mainly cover low, medium and high voltage (KV) crosslinked polyethylene insulated power cable,PVC insulated power cable, PVC insulated wire (construction cable), control cable, signal cable, rubber cable,coal mine cable, welding cable, ship cable and other related customized cables. These cables are used in Power metallurgy, Oil&Chemical Industry, Nation Defense Power Station, Mine, Port and Architectural Engineering, andother fields.
Q3:Which standards do you comply with when you produce the electrical wires and cables ?
A3: We have passed ISO9001:2000 and ISO140001:2004. All products conform to GB, IEC, BS, ASTM, VDE JB and UL standards. Besides, we have the ability to design and produce various wires and cables, and customize them for you according to the special requirements of customers (providing OEM services).
Q4: What is your MOQ?
A4: It`s base on the cable type or wire type. Please contact Calder. He will let you know.
Q5:How much the Courier freight will be for the samples?
A5:Courier freight depends on the quantity,weight and carton size and your area.