Customization: | Available |
---|---|
Type: | Insulated |
Conductor Type: | Solid |
Still deciding? Get samples of US$ 10/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Performance:
Cable Type | RG58A/U | RG58/U | RG58C/U | ||||
Inner Conductor | Tinned/Plain Copper | 19*0.18mm | φ0.80mm | 19*0.18mm | |||
Dielectric | Low Density PE | φ2.95mm | φ2.95mm | φ2.95mm | |||
Outer Conductor(Shield) | Tinned Copper | 144*0.10mm | 112*0.13mm | 112*0.13mm | |||
Shield Coverage | 93% | 95% | 95% | ||||
Sheath | PVC/LSZH | φ5.00mm | φ5.00mm | φ5.00mm | |||
Cable Type | RG58A/U | RG58/U | RG58C/U | ||||
Impedance | 50±3 Ohm | 50±3 Ohm | 50±3 Ohm | ||||
Nominal Capacitance | 100 pF/m | 94 pF/m | 100 pF/m | ||||
Velocity of Propagation | 66% | 66% | 66% | ||||
Insulation Resistance | >2000 Mohm. Km | >2000 Mohm. Km | >2000 Mohm. Km | ||||
Inner Resistance | 37.5 Ohm/Km | 35.0 Ohm/Km | 37.5 Ohm/Km | ||||
Outer Conductor Resistance | 17 Ohm/Km | 16.5 Ohm/Km | 16.5Ohm/Km | ||||
Test/Operating Voltage(Max) | 5KV/2KV | 5KV/2.5KV | |||||
Operating Temperature Range | -30ºC~+70ºC | -30ºC~+70ºC | -30ºC~+70ºC | ||||
Screening Effectiveness(100-900MHz) | >55 dB | >55 dB | >55 dB | ||||
Return Loss | RG58A/U | RG58/U | RG58C/U | ||||
30-300 MHz | ≥27 dB | ≥26 dB | ≥27 dB | ||||
300-600 MHz | ≥23dB | ≥25dB | ≥23dB | ||||
600-900 MHz | ≥22 dB | ≥24 dB | ≥22 dB | ||||
Frequency(MHz) | Attenuation(dB/100m) | Attenuation(dB/100ft) | |||||
RG58A/U | RG58/U | RG58C/U | RG58A/U | RG58/U | RG58C/U | ||
50 | 9.7 | 9.1 | 10.8 | 2.96 | 2.77 | 3.29 | |
100 | 13.9 | 13.1 | 16 | 4.24 | 3.99 | 4.88 | |
200 | 20.4 | 19.4 | 24 | 6.22 | 5.91 | 7.32 | |
400 | 30 | 28.4 | 37.7 | 9.15 | 8.66 | 11.49 | |
500 | 34.2 | 32.2 | 41.3 | 10.43 | 9.82 | 12.59 | |
600 | 37.9 | 35.7 | 49.7 | 11.55 | 10.88 | 15.15 | |
860 | 46.9 | 44.8 | 64.2 | 14.3 | 13.66 | 19.57 | |
1000 | 51.8 | 49 | 70 | 15.79 | 14.94 | 21.34 |
Cable Type | RG213 | |
Conductor | Material | BC |
Nom.Dia. | 7*0.75mm(2.25mm) | |
Dielectric | Material | PE |
Nom.Dia. | 7.24mm | |
Shield 1 | Braiding | 240*0.13 BC-93% |
Shield 2 | Braiding | / |
Jacket | Material | PVC/PE |
Nom.Dia. | 10.3±0.10mm | |
Cable Type | RG213 | |
Impedance | 50±3 Ohm | |
Nominal Capacitance | 100 pF/m | |
Velocity of Propagation | 66% | |
Insulation Resistance | >2000 Mohm. Km | |
Inner Resistance | 6 Ohm/Km | |
Outer Conductor Resistance | 7 Ohm/Km | |
Operating Temperature Range | -30ºC~+70ºC | |
Screening Effectiveness | >55 dB | |
Return Loss | RG213 | |
30-300 MHz | ≥31 dB | |
300-600 MHz | ≥28 dB | |
600-900 MHz | ≥27 dB | |
Frequency(MHz) | Attenuation(dB /100m) | Attenuation(dB /100ft) |
50 | 4.50 | 1.37 |
100 | 6.80 | 2.07 |
200 | 10.00 | 3.05 |
400 | 14.50 | 4.42 |
500 | 16.40 | 5.00 |
600 | 18.10 | 5.52 |
860 | 22.50 | 6.86 |
1000 | 24.70 | 7.53 |