• 0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
  • 0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
  • 0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
  • 0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
  • 0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
  • 0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire

0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire

Type: Insulated
Conductor Type: Stranded
Application: Overhead, Underground
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: PVC
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
NA2XY
Material Shape
Round Wire
Range of Application
Construction, Overhead, Underground, Industrial,
Certification
CE, CCC, RoHS, VDE
Brand
Fengda
Color
Black Red Yellow, According to Voltage Level
Whether It Is Environmentally Friendly
Yes
Whether Quality Inspection
Provide Inspection Certificate
Standard
Customized According to Specified National Standar
OEM/ODM
Accepted
Core
Single Core and Multicore
Transport Package
Standard Export Packaging
Specification
International General Specifications
Trademark
Fengda
Origin
Tianjin, China(Mainland)
HS Code
8544492100
Production Capacity
100000/Day

Product Description

  

NYCWY

PCV Insulated Heavy Current Cable with Concentric Conductor

Application:

In dry, humid and wet locations, cable ducts, outdoors, underground and in Water.
0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire

 

Construction:

1 ..... solid or stranded bare copper wire
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... PVC core covering
4 ..... concentric conductor of copper wires and copper tape applied helically
5 ..... outer sheath of polyvinylchloride (PVC), black

 

Standards:

DIN VDE 0276-627
HD 627 S1:1996 part 1 4H1, 4H2.7H
DIN EN 60228 class 1 and 2 (construction)
HD 308 S2 (core identification)

Cable Parameter

AWG NO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM² STRANDED CONDUCTOR TYPE NOMINAL OVERALL DIAMETER MM NOMINAL COPPER WEIGHT KG/KM NOMINAL CABLE WEIGHT KG/KM
8 2 x 10.0 re / 10.0 19 312 650
6 2 x 16.0 re / 16.0 21.5 489 850
4 2 x 25.0 rm / 25.0 24.5 763 1210
8 3 x 10.0 re / 10.0 19.5 408 730
6 3 x 16.0 re / 16.0 22 643 1000
4 3 x 25.0 rm / 16.0 26 902 1550
4 3 x 25.0 rm / 25.0 26 1003 1600
2 3 x 35.0 sm / 35.0 27.5 1402 1850
2 3 x 35.0 sm / 16.0 27 1190 1750
1 3 x 50.0 sm / 50.0 29.5 2000 2450
1 3 x 50.0 sm / 25.0 29 1723 2250
2/0 3 x 70.0 sm / 70.0 34 2796 3350
2/0 3 x 70.0 sm / 35.0 33 2410 2950
3/0 3 x 95.0 sm / 95.0 38.5 3791 4550
3/0 3 x 95.0 sm / 50.0 38 3296 4100
4/0 3 x 120.0 sm / 70.0 41 4236 5050
4/0 3 x 120.0 sm / 120.0 42 4786 5550
300mcm 3 x 150.0 sm / 70.0 45 5100 6000
300mcm 3 x 150.0 sm / 150.0 46 5970 6900
350mcm 3 x 185.0 sm / 95.0 50 6383 7550
350mcm 3 x 185.0 sm / 185.0 51 7363 8500
500mcm 3 x 240.0 sm / 120.0 57 8242 9950
8 4 x 10.0 re / 10.0 20.5 504 890
6 4 x 16.0 re / 16.0 23.5 796 1250
4 4 x 25.0 rm / 16.0 28 1142 1800
2 4 x 35.0 sm / 16.0 29 1526 2050
1 4 x 50.0 sm / 25.0 33 2203 2700
2/0 4 x 70.0 sm / 35.0 37 3082 3750
3/0 4 x 95.0 sm / 50.0 43.5 4208 5000
4/0 4 x 120.0 sm / 70.0 47 5388 6350
300mcm 4 x 150.0 sm / 70.0 51 6540 7650
350mcm 4 x 185.0 sm / 95.0 56 8159 9350
500mcm 4 x 240.0 sm / 120.0 62.5 10546 11600

Technical data:

Nominal voltage Uo/U   [V] 600 / 1000 volt
Test voltage   [V]AC 4000
Temperature range in motion   -5°C till +70°C
  fixed   -20°C till +70°C
Operating temperature short circuit °C 160
Short circuit time max. [sec] 5
Bending radius one time / fixed x diameter 12
  in motion x diameter 15
Flammability standard   EN 60332-1-2

0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire

 
0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire
0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire0.6/1kv Aluminium Conductor XLPE Insulated PVC Jacket Underground Armoured Power Cables Electrical Wire

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now