Application:
Orange circular cables are widely used in the power networks and power distribution systems. They are normally installed for mains, sub mains and sub circuits unenclosed as well as enclosed in conduit buried direct or underground ducts for buildings and industrial plants. They are only to be allowed to use in the situation were not subject to mechanical damage are suitable for glanding.
Construction:
2C+E PVC Insulated Orange Circular Cables 450/750V, Cu
3C+E PVC Insulated Orange Circular Cables 450/750V, Cu
4C+E PVC Insulated Orange Circular Cables 450/750V, Cu
Description
Conductor: Class 2 Plain Annealed Copper
Insulation: PVC V-90
Sheath: PVC 5V-90
Core identification
2C+E:Red, Black, Green/Yellow
3C+E: Red, White, Blue, Green/Yellow
4C+E:Red, White, Blue, Black, Green/Yellow
Sheath Colour
Orange
Technical Data
Voltage Rating: 450/750V
Operating Temperature: -25°C to +75°C, Maximum 90°C*
*Not subject to severe mechanical pressure at temperatures
higher than 75°C.
Standards Compliance
AS/NZS 5000.2 AS/NZS 1660.5.6 (Equivalent to IEC 60332-1)
AS/NZS 3808 AS/NZS 1660.5.1 (Equivalent to IEC60332-3-24)
AS/NZS 1125
Product Images
Specifications
Number of cores |
Conductor Size (mm2) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Earth Conductor Size (mm2) | Approx. Overall Diameter (mm) | Min. Bending Radius (mm) | Approx. Weight (kg/km) |
|
During Installation | After Installation | |||||||
2C+E | 1.5 | 1.56 | 0.6 | 1.5 | 8.4 | 79 | 53 | 113 |
2C+E | 2.5 | 2.01 | 0.7 | 2.5 | 10.0 | 95 | 63 | 170 |
2C+E | 4 | 2.55 | 0.8 | 2.5 | 11.0 | 104 | 69 | 213 |
2C+E | 6 | 3.12 | 0.8 | 2.5 | 11.9 | 112 | 75 | 258 |
Number of cores |
Conductor Size (mm2) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Earth Conductor Size (mm2) | Approx. Overall Diameter (mm) | Min. Bending Radius (mm) | Approx. Weight (kg/km) |
|
During Installation | After Installation | |||||||
3C+E | 1.5 | 1.56 | 0.6 | 1.5 | 9.1 | 86 | 57 | 136 |
3C+E | 2.5 | 2.01 | 0.7 | 2.5 | 10.9 | 103 | 69 | 208 |
3C+E | 4 | 2.55 | 0.8 | 2.5 | 12.2 | 115 | 77 | 271 |
3C+E | 6 | 3.12 | 0.8 | 2.5 | 13.4 | 127 | 84 | 343 |
Number of cores |
Conductor Size (mm2) |
Conductor Diameter (mm) |
Insulation Thickness (mm) |
Earth Conductor Size (mm2) | Approx. Overall Diameter (mm) | Min. Bending Radius (mm) | Approx. Weight (kg/km) |
|
During Installation | After Installation | |||||||
4C+E | 1.5 | 1.56 | 0.6 | 1.5 | 10.1 | 95 | 64 | 175 |
4C+E | 2.5 | 2.01 | 0.7 | 2.5 | 11.8 | 112 | 74 | 247 |
4C+E | 4 | 2.55 | 0.8 | 2.5 | 13.6 | 129 | 86 | 348 |
4C+E | 6 | 3.12 | 0.8 | 2.5 | 14.8 | 140 | 93 | 434 |